During servicing, we’ll check all safety components of your unit.
Checking the general condition of the Vacuum Paver Life
Checking the load-bearing components for wear, deformation, and other damage.
The vacuum generator is working,
but the load is not being drawn in.
The filter screen is dirty
Position the vacuum gripper so that the suction plate is completelyflush with the load
Clean the filtering sieve.
MThe 0.25 bar minimumvacuum cannot be reached.
The transported load is porous or has cracks andindentations
This vacuum gripper is not suitablefor transporting this type of load.
The sealing edge of thethe suction plate is damaged
Replace the suction plate.
Faulty manometer.
Replace the manometer.
Working at altitudes above 1600m.
Follow the maximum altitude limits.